|
Physiotherapists and other practitioners specialising in lower bowel dysfunction now have a range of specialist catheters designed for the treatment of fecal incontinence and related disorders.
These catheters are custom-designed for easy and effective pressure biofeedback therapy and retraining.
|
The Ashley2 Catheter (ARC 2415/10, ARC 2415/100) The Ashley2 has a 400mm PVC tube section fitted with a large, non-latex polyisoprene balloon for maximum physiological compliance, which may be inflated up to 600ml if needed. A 3-way tap is fitted to the proximal end of the catheter, to enable easy and controlled inflation/deflation in stages. Ashley2 Catheters are available in a box of 10, individually peel-pouched, or 100x bulk-packed for easy handling in a busy clinic. |
 |
The Bolton Catheter (ARC 2105) Designed for anorectal pressure biofeedback retraining, the Bolton Catheter has 2000mm Ch6 PVC tubing to enable rapid inflation, deflation and response and is fitted with a luer connector and 3-way tap.
The catheter has a green neoprene balloon and comes fitted with a 100mm stiffened introducer to enable easy insertion by either the practitioner or the patient and a moveable silicone flange for easy placement. |
 |
The Bovingon Catheter (ARC 2470)
The Bovingdon Catheter is suitable for both intra-vaginal and anorectal pressure biofeedback training.
The 70mm shaped silicone balloon is fitted to a 400mm catheter tube,and a proximal 3-way tap. The balloon may be inflated with air or water up to a capacity of 500ml. The Bovingdon ARC catheter is available in a box of 20, individually peel-pouched. |
 |
The Langley Biofeedback Catheter (ARC 2205) This biofeedback catheter has two balloons fixed in tandem on one 2-channel shaft, each connected to a 1500mm color-coded pressure line. Each line is Ch6 and fitted with a 3-way tap to enable rapid inflation and deflation. A moveable silicone flange ensures the catheter will not ingress further into the bowel once placed by the practitioner. The Langley Biofeedback Catheter is specially designed to assist the practitioner with certain specific biofeedback practices: sphincter resting and squeeze pressures, and measurement of sensitivity threshold and monitoring progress whilst teaching sphincter re-education exercises. |
 |
The Ashley2 Catheter The Bolton Catheter
|
• 400mm-long PVC catheter tubing
• Large 600ml capacity, bendy and physiologically compliant balloon
• Balloon is polyisoprene (non-latex)
• Balloon is white, to assist in the visual diagnosis of pathologies
• 3-way tap fitted as standard to all catheters
• Industrially manufactured to comply with ISO13485:2003, MDD93/42/EEC, CE-Marked • FDA listed
• Single use, non-sterile | • 2000mm Ch6 catheter tubing for ease of inflation/deflation
• Luer connector and 3-way tap
• Green neoprene balloon
• 100mm stiffened introducer incorporated into catheter/balloon intersection to enable easy placement by practitioner or patient • Moveable silicone flange prevents catheter ingress
• Industrially manufactured to comply with ISO13485:2003, MDD93/42/EEC,CE-marked • FDA listed
• Single use, non-sterile |
The Bovingdon Catheter The Langley Catheter
|
• 400mm long PVC catheter tubing
• Shaped, cylindrical, silicone balloon
• Latex-free
• Balloon is 70mm long, with 500ml fill-capacity • Suitable for both intra-vaginal or ano-rectal biofeedback training
• 3-way tap fitted as standard
• Industrially manufactured to comply with ISO13485:2003, MDD93/42/EEC, CE-Marked • FDA listed • Single use, non-sterile | • Two polyisoprene balloons fitted in tandem on a Ch14, 2-channel shaft • Shaft is stiffened but also bendy and compliant to enable easy insertion with maximum patient comfort • Moveable silicone flange prevents catheter ingress • 2x color-coded Ch6, 1500mm long pressure lines • Each pressure line fitted with 3-way tap • Use for resting/squeeze pressures, measuring sensitivity and retraining • Industrially manufactured to comply with ISO13485:2003, MDD93/42/EEC, CE-marked • FDA listed • Single use, non-sterile |
| order code description catheters per box ARC 2415/10 Ashley2 balloon catheter: 400mm catheter tubing with 10 600ml polyisoprene balloon & 3-way tap. Individually peel-pouched ARC 2415/100 Ashley2 balloon catheter: 400mm catheter tubing with 100 600ml polyisoprene balloon & 3-way tap. Double bagged in bulk for easy handling in clinic ARC 2105 Bolton biofeedback trainer catheter. 2000mm with neoprene 20 balloon, introducer & 3-way tap ARC 2470 Bovingdon reflex balloon catheter: 400mm catheter tubing 20 with 70mm silicone balloon & 3-way tap. Individually peel-pouched ARC 2205 Langley 2-lumen, polyisoprene twin-balloon biofeedback catheter includes 3-way tap on each line 5 |
For PDF version click here |